100V PA mixer amp


Toa Dedicated integrated PA/voice-evac multizone mixer amp with emergency/mic-priority & back ground music (bgm) facilities for up to 5 speaker zones. Optional EV200 digital message board. Optional SV200M Surveillance Board monitors speaker lines etc, displaying faults on VM front panel or output to alarm panel etc. Optional RM200M desk mic allows remote activation of EV200 pre-recorded messages or live announcements into any or all 5 zones. Two VM amps may be linked & combined for extra inputs & power. 3 balanced mics, 2 bgm aux & telephone paging inputs. 100V input for feed from remote PA system. Various built-in remote-activating tones. 120W 100V total power rating, AC & 24Vdc.



Power Requirement AC mains, 50/60 Hz DC: 24 V
Output 120 W
Frequency Response 50 - 16,000 Hz
Distortion Less than 1%
Signal-to-Noise Ratio More than 60 dB
Tone Control Bass: 100 Hz }10 dB, Treble: 10 kHz }10 dB (Inputs 1 - 3 and BGM individually adjustable.)
Remote Microphone/Extension Amplifier Connection Two RJ45 female connectors Maximum distance: 800 m
Audio Input
Inputs 1 ~ 3 -60 dB [MIC]/-10 dB [LINE] (switchable), 600 ohms, electronically balanced, combined XLR type connector (female)/ 1/4" phone jack (Only Input 1 is additionally (female)/ 1/4" phone jack (Only Input 1 is additionally equipped with DIN connector.)
Telephone Paging Input Push-in terminal block
-10 dB, 10 k ohms, electronically-balanced
Control : No-voltage make contact input
BGM 1 - 2 -20 dB, 10 k ohms, RCA pin jack, monaural
Power Amplifier Input 0 dB, 10 k ohms, RCA pin jack
External Speaker Line Input 100 V line, for All-Zone Broadcast
Audio Output
Speaker Output 83 ohms (100 V line, volume control in maximum position), Removable terminal block with screw terminals.
Speaker Zone Control 5-zone selector with attenuator
Direct Speaker Line Output Direct output from the power amplifier output transformer,
Line Output 0 dB, 10 k ohms, RCA pin jack
Recording Output 0 dB, 10 k ohms, RCA pin jack
Preamplifier Output 0 dB, 10 k ohms, RCA pin jack
Control Inputs 1 - 3 For controlling Inputs 1 - 3, Push-in terminal block
No-voltage make contact.
Control Input and Output Control Input and Output
Input : No-voltage make contact input
Output : Open collector output
(1) External control input

Activation of messages for an optional Voice Announcement Board
Activation of power
Activation and stop of Emergency Broadcast
Unit's broadcast cutoff (when activated by an external emergency equipment)
(2) Status output

Irregularity of communications with the Remote Microphone and an expansion amplifier
AC power condition
DC power condition
Irregularity of the sound source of the Voice Announcement board
Stop of the unit's broadcast

External Attenuator Control Output Removable terminal block with screw terminals, relay, no-voltage make contact output, transfer type
Surveillance Input and Output 25-pin female D-sub connector
Input : No-voltage make contact input
Output : Open collector output
Power Output 24 V DC
Chime Tone Built-in chime:
2-tone chime/2-tone chime(fast repeat)
4-tone chime (Up)/Single-tone chime/
4-tone chime (Up & Down)/Gong/off

Finish Panel: ABS resin
Case: Steel plate painted
Dimensions 419 (W) 143.3 (H) 356.2 (D) mm

     Add to basketBasketAdd to favourites

 